Hesai Hesai · LiDAR LiDAR

Hesai OT128 Long-Range 3D LiDAR

LiDAR, which provides circumferential point cloud, can be used as a remote environment sensing and data collection device for mobile robots. Target distance, vertical coverage and installation height are evaluated together when selecting.

LiDAR
200 m Ranging (10% reflectivity)
360° × 40° field of view
128 line Number of lines
Placeholder Hesai Hesai OT128 long distance 3D LiDAR product appearance, AI transparent background finishing
Product illustration

Overview

  • 360° Horizontal environment scan
  • 200 m @10% reflectivity, furthest range 230 m
  • Single return: 3,456,000 points/s
  • Official ROS Driver and SDK Resources

Typical tasks

  • Outdoor environment point cloud collection
  • Mobile robot surrounding perception
  • Multi-sensor data logging

What to consider

  • Compare coverage responsibilities with directional and near-field LiDAR to avoid looking solely at the ranging upper limit.
  • The installation point needs to consider obstruction, vibration and overall machine load.
  • When parallel collection and navigation are required, network and storage bandwidth will be evaluated separately.

Specifications & Interfaces

Switches the displayed specifications only. Purchase and inquiry configurations are selected separately.

Key specifications
Ranging distance
Ranging range: 200 m Farthest range: 230 m Nearest ranging/blind zone: 0.3 m
Conditions
  • 10% reflectivity
  • The farthest range of the official website 230 m is not equivalent to 10% reflectivity ranging
  • Instrument range 0.3–230 m
  • Range at 10% reflectivity: 1–200 m; 100 klux; PoD>70%
Field of view (FOV)
H 360° / V 40°
Channels / Array
128 line
Angular resolution
H 0.1° / V 0.125°
Point rate
Single echo point frequency: 3,456,000 point/s Dual echo point frequency: 6,912,000 point/s
Frame rate
10 / 20 Hz
Ranging accuracy
±3 cm
Conditions
  • 3–200 m typical value
  • 80% channel meets this range when 3/7/15/30 m, 10%–90% target reflectivity at room temperature
  • Not equivalent to all channel guarantees
Data interface
1000BASE-T1
Conditions
  • O01-en-260310
Power supply
9–32 V DC
Dimensions & Weight
Size: Diameter 118 × Height 132.3 mm Weight: 2.2 kg
Operating environment
Temperature: −40–+75 °C Protection: IP6K7 / IP6K9K
Additional measured specifications
Additional measured specifications
echo mode
Support single echo and dual echo
Laser safety level
Class 1
Other power & installation specifications
Other power & installation specifications
Other power supply parameters
Rated/Typical power consumption: 29 W Peak and minimum power capabilities: 35 W
Other interfaces & features
Other interfaces & features
Point cloud data rate
The maximum single echo is 130.61 / the maximum dual echo is 261.22 Mbps
Connectors and cables
TE Connectivity 2387351-1 (radar male connector)
Conditions
  • O01-en-260310 Section 2.2
  • Supporting cables, connection boxes and sales packaging are confirmed separately.
Synchronization
PTP(802.1AS Automotive / AUTOSAR)
Conditions
  • Typical clock accuracy at room temperature ≤1 μs
  • Loss of lock drift≤1 μs/s
System & software scope
HesaiLidar_ROS_2.0 official driver repository lists this model

Components & Accessories

Product & configuration scope

  • OT128 sensor and confirmed interface configuration
  • Connecting cables, power supplies and mounting hardware are checked according to the configuration list

Accessory selection

  • Model-matched power and data cables
  • Installation brackets and protective structures
  • Network, time synchronization and data recording conditions

Included items, options, wiring harnesses and mounting hardware are confirmed according to the selected model and system configuration.

Software and usage support

  • can refer to the Hesai official driver to read the point cloud.
  • target RDK environment also needs to check driver dependencies, network and resource overhead.

Operating conditions

  • ranging depends on target reflectivity, ambient light, weather and installation occlusion.
  • mobile system also needs to complete coordinate calibration, clock synchronization and network bandwidth configuration; a single Sensor is not equivalent to a complete navigation system.

Models and optional configurations

OT128 · 128 line

360° × 40° field of view, 200m@10% reflectivity; equipment interface and Power supply accessories are based on the complete model accessories.

Technical resources

When using these documents, please check the product model, hardware configuration and document version.

Learn about related components

Explore the compute, perception and mobile platforms used in related solutions; see each solution for compatibility conditions and options.

Configuration and backup tools

Edit selection list

  1. 01 Review configuration Model, version and quantity
  2. 02 Describe your application Application, environment and goals
  3. 03 Save summary Copy or download for discussion

Not sent yet. Your list is stored in this browser. Copy or download it to share with RJ.

Edit the full configuration, product selection and project notes here, or restore and download a backup. View full selection list 。

Packages & individual products 0

Packages list their included, extra and customer-supplied items according to the configuration; individual products keep their own quantities.

Application & contact details

You can describe your project without selecting products. Contact details are optional and stay in this browser.